Promise Technology Network Card SX4000 Lite User Manual

FastTrak  
SX4000 Lite  
Quick Start Guide  
Version 3.4  
 
Quick Start Guide  
Step 1: Unpack Your FastTrak Card  
When you receive the FastTrak SX4000 Lite, the package should contain the  
items listed below:  
FastTrak SX4000 Lite Controller Card  
Quick Start Guide  
FastTrak SX4000 Lite driver diskette  
Four Internal 18 inch (46 cm) Ultra ATA, 80-wire/40-pin hard drive  
cables  
Two Y-cable power splitters  
CD with Drivers, Promise Array Management (PAM) utility, PAM User  
Manual and FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual  
If any of the items are missing or appear damaged, please contact your dealer  
or distributor immediately.  
Note  
The Promise card is a PCI Plug-n-Play (PnP) device. No  
changes are necessary in the motherboard CMOS/BIOS Setup  
for resources or drive types in most applications.  
Warning  
Before installing the adapter into an existing system, backup any  
important or useful data. Failure to follow this accepted PC  
practice could result in data loss.  
Warning  
The FastTrak card, like other parts of your system, is subject to  
damage by static electricity. Be sure that you’re properly  
grounded (Promise Technology recommends that you wear an  
anti-static strap or touch a grounded object) and that you unplug  
your system before installing FastTrak.  
3
 
FastTrak SX4000 Lite  
Step 2: Memory Module Test  
The FastTrak SX4000 Lite RAID Controller card ships without a Dual Inline  
Memory Module (DIMM) for Synchronous Dynamic Random Access Memory  
(SDRAM). A DIMM of 64 MB to 256 MB capacity must be installed in order for  
the FastTrak Card to function.  
The DIMM you select must pass a test prepared by Promise Technology to  
verify that your DIMM is fully compatible with the FastTrak card. An incompatible  
DIMM can appear to work properly, only to experience unexpected errors that  
may result in data loss or controller malfunction.  
Promise recommends testing for all DIMMs being used in a FastTrak controller,  
including those from the above list. Follow this procedure to verify your DIMM's  
compatibility with your FastTrak RAID Controller card.  
1. Prepare a DOS Boot diskette.  
2. Copy the Promise Test Utility files to a second diskette.  
3. Install your SDRAM DIMM into the Cache Memory socket of the FastTrak  
card.  
4. Plug in FastTrak card into a PCI slot on a desktop PC or server.  
5. Boot the PC with the DOS Boot diskette.  
6. Remove the DOS Boot diskette and insert the diskette with the Promise  
Test Utility files.  
7. At the DOS prompt, type memtest and press Enter. The test begins.  
If the DIMM is OK, the program will show a PASS message similar to  
the one below:  
Promise Memory Test Utility V1.3  
05/24/2003 18:07:50  
Controller Type................. : FastTrak  
SX4000  
Memory Speed.................... : 100MHz  
Memory Size..................... : 128MB  
Memory Type..................... : Non-ECC  
Memory Test Result ( HOST )..... : PASS  
Memory Test Result ( HDMA )..... : PASS  
Memory Test Result ( XOR )..... : PASS  
The PASS message means you can use the DIMM that is currently  
installed.  
If there is any error, the program will stop and return to DOS and show  
error message. Do not use the DIMM.  
If the program halts for more than 20 seconds, there may be an error.  
Check the FastTrak card, DIMM, and your system BIOS. Then run the  
test again.  
4
 
Quick Start Guide  
Step 3: Install the FastTrak Card  
The FastTrak RAID Controller card fits into any available:  
33-MHz, 32-bit PCI slot (must be PCI 2.2 compliant)  
The 33-MHz, 32-bit portion of a 64-bit PCI slot  
on the PC’s motherboard (see Figure 1 below).  
1. Remove the cover of your system.  
2. Remove the inside slot cover of an available 33-MHz, 32-bit PCI slot on the  
motherboard.  
3. Install the FastTrak card into the open slot (see Figure 1 below). Secure the  
bracket to the system’s frame.  
4. Attach your system case’s 2- or 4-pin LED cable to the LED connector on  
the FastTrak card (see Figures 2 and 3, below). Make sure that pin 1 on the  
connector is aligned with pin 1 of the cable.  
5. Fasten the FastTrak card bracket to the system case (see below).  
Figure 1.  
Insert the FastTrak card into an open PCI slot.  
5
 
FastTrak SX4000 Lite  
Step 4: Install the Hard Drives  
Important  
If you wish to include your current bootable Serial ATA drive  
using the Windows XP operating system as part of a bootable  
Mirrored (RAID 1) array on your FastTrak card, do NOT connect  
the hard drive to the FastTrak yet.  
You MUST install the Windows XP driver software first onto this  
drive while it is still attached to your existing hard drive controller.  
The FastTrak SX4000 Lite RAID Controller card supports only (Parallel) ATA  
hard drives.  
If you are striping (RAID 0) for performance, use up to four new drives. If  
mirroring (RAID 1) for protection, you can use two new drives OR use an  
existing drive and a new drive (the new drive must be the same size or larger  
than the existing drive). If you are planning a RAID 5 array, use three or four  
new drives.  
1. Set your hard drives to Master, Cable-Select or Single (depending on drive  
specification).  
2. Install the hard drives into the hard drive bays of your system.  
Caution  
Use of removable hard drive enclosures other than Promise  
Technology’s SuperSwap is not supported and may result in  
performance loss or other undesired results.  
3. Attach the black end of the Ultra ATA cable to each hard drive. Then attach  
the blue end to the ATA connectors on the FastTrak card (see Figure 2,  
below).  
6
 
Quick Start Guide  
LED Pins  
Ch1  
Ch2  
Ch3  
Ch4  
Buzzer  
1
1
1
1
SX4000 Lite  
FastTRAK  
J
1
Cache Memory Socket  
SDRAM DIMM  
(Not included.  
See Step 2)  
Figure 2.  
FastTrak SX4000 Lite card.  
4. Attach the Y-cable power splitters to each of the hard drives.  
7
 
FastTrak SX4000 Lite  
Step 5: Create Your Disk Array  
You will now use the onboard FastBuild BIOS utility to create your first array  
using the attached drives. For an explanation of the array options, see Chapter 3  
of the FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual.  
Important  
Even if you plan to use the Promise Array Management Utility to  
manage your array, you must still create your first array using  
the FastBuild Utility, as described here.  
1. Boot your system. If this is the first time you have booted with the FastTrak  
card and drives installed, the Promise onboard BIOS will display the  
following screen.  
FastTrak S150 SX4 (tm) BIOS Version 1.10.02  
(c) 2002 Promise Technology, Inc. All rights reserved.  
Installed DIMM Size: 128 MB  
No Array is defined...  
Press <Ctrl-F> to enter FastBuild (tm) Utility...  
<
Press <ESC> to continue booting...  
2. Press the Ctrl-F keys to display the FastBuild Utility Main Menu (below).  
FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.  
[ Main Menu ]  
View Drive Assignments .......[ 1 ]  
View/Define Array.............[ 2 ]  
Delete Array..................[ 3 ]  
Controller Configuration......[ 4 ]  
[ Keys Available ]  
Press 1..4 to Select Option  
[ESC]..Exit  
3. Press 2 on the Main Menu screen to display, the Define Array Menu  
appears (below).  
8
 
Quick Start Guide  
FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.  
[ Define Array Menu ]  
Array No  
RAID Level  
Total Drv  
Capacity (MB)  
Status  
Array 1  
Array 2  
Array 3  
Array 4  
-----  
-----  
-----  
-----  
-----  
-----  
-----  
----  
-----  
-----  
-----  
-----  
-----  
-----  
-----  
-----  
[ Keys Available ]  
Note: * --Bootable Array  
[ ] Up [ ] Down [ESC] Exit [Enter] Select [Space] Change Boot Drive  
4. Press the arrow keys to highlight an array number you wish to define and  
press Enter to select it. The Define Array Definition Menu will next appear  
(below).  
FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.  
[ Define Array Definition Menu ]  
Array No  
Array 1  
RAID Level  
RAID 5  
Total Drv  
3
Status  
Functional  
Stripe Block: 64 KB  
Initialize Array: ON Gigabyte Boundary: ON  
[ Drive Assignments ]  
Channel ID  
Drive Model  
Capacity (MB)  
Assignment  
1:  
2:  
3:  
4:  
SEAGATEST380023AS  
SEAGATEST380023AS  
SEAGATEST380023AS  
SEAGATEST380023AS  
80630  
80630  
80630  
80630  
Array 1  
Array 1  
Array 1  
Free  
[ Keys Available ]  
[ ] Up [ ] Down [Space] Change Option [ESC] Exit [Ctrl-Y] Save  
5. Choose the RAID Level you want. In the Define Array Definition Menu  
section, press the Spacebar to cycle through array types:  
RAID 0 (Striping)  
RAID 1 (Mirroring)  
RAID 0+1 (Striping / Mirroring)  
RAID 5 (Data / Parity Striping)  
JBOD (Single Drive)  
9
 
FastTrak SX4000 Lite  
6. Press the arrow keys to move to the next option. Option choices depend on  
the RAID Level you selected.  
Initialize Array, zero the disk drives. RAID 5 only.  
Stripe Block Size, the default 64KB is best for most applications.  
Gigabyte Boundary, allows use of slightly smaller replacement drives.  
7. Press the arrow keys to move to Disk Assignments. Press the spacebar to  
toggle between N and Y for each available drive.  
Assign the appropriate number of disk drives to your array. Refer to the  
chart below:  
Level  
Number of Drives  
2, 3 or 4  
2 only  
RAID 0  
RAID 1  
RAID 0+1  
RAID 5  
JBOD  
4 only  
3 or 4  
1, 2, 3 or 4  
A disk drive that is not assigned to an array will automatically function as a  
Hot Spare Drive.  
8. Press Ctrl-Y to save your array configuration.  
9. Press Esc to exit to the Main Menu. Press Esc again to exit the Utility.  
10. Press Y to confirm the new array and restart the computer.  
You have successfully created a new RAID array.  
Important  
You must be partition and format your new array before you can  
use it. Use the same method of partitioning and formatting on an  
array as you would any other fixed disk added to your computer  
system.  
.
10  
 
Quick Start Guide  
Step 6: Install Software Drivers  
Drivers for the Windows operating systems are included on the software CD and  
driver diskette that came with your FastTrak SX4000 Lite Controller. Please  
Windows systems usually recognize the FastTrak Controller, prompt you for the CD  
or diskette and perform the driver installation automatically.  
If you are installing the FastTrak Controller at the same time as your operating  
system or you prefer to read step-by-step directions, see Chapter 4 of the FastTrak  
S150 SX4 / SX4000 / SX4000 Lite User Manual on the software CD.  
Drivers and installation instructions for other Operating Systems are downloadable  
11  
 

Peavey Stereo Equalizer RTD 215 User Manual
Philips Indoor Furnishings 34615 17 36 User Manual
Philips Printer Accessories WACS7500 User Manual
Pioneer Stereo Receiver VSX D511 User Manual
Plantronics Headphones WO101 User Manual
PLUS Vision Projector U4 112 U4 111 User Manual
Polaroid Digital Camera i733 User Manual
Poulan Tiller 159399 User Manual
Presonus Audio electronic Stereo Amplifier D8 User Manual
PYLE Audio Car Video System PLVWR71IR User Manual